Often being constructed in less than a day, these pads are readily available for immediate installation without waiting for curing like pour-in-place alternatives. iPod touch Requires iOS 14.0 or later. iPad Requires iPadOS 14.0 or later. 10 minimum from front of concrete.) With Duke Energy's Builder Portal, you have the tools you need to get it done, right at your fingertips. Listed below are instructions for building a transformer pad on site. 14 - 24 #4 Reinforcing Bars 6 min (Note 3) (Primary) See Note 5 (Secondary) 12 34 22 2 12 See Note 2 1) Pad to be a Minimum of 5 - 1/2 Thick 2) Shaded area around pad indicates minimum clearance from obstructions. 9696-Pit-Box-Pad-1.pdf. Sitemap, 1419 Alexandria Pike, 8. Do Not Sell Or Share My Personal Information, Offers a simple rugged design for a strong foundation. 0000004177 00000 n Specs & Guides Material: Concrete. Additional costs will incur for shipping and handling. Because the SERC Supplement, Key Reference #2, contains more detailed requirements and has assembled them in a manner different from the NERC Standard, Entergy has chosen to format and address the text and spreadsheet documents in the order presented in the SERC Supplement. Link:https://www.serc1.org/program-areas/standards-regional-criteria/regional-criteria-and-guidelines, SCOPE This web site and the documents it refers to serve as a reference to parties (Connecting Customers) that are either considering connecting to or modifying facilities that are already connected to the Entergy Transmission system. Call us if you dont see what youre looking for, we make custom sized pads as well. Flat Pad and Pit Pad Application and Construction The information contained in this document has been prepared to assist both Duke Energy personnel and Duke Energy customers in the application and construction of foundations for all 3-phase padmount transformers. Looking for a quote for your project? (There may be some rare exceptions.) Impact Study Requirements and Provisions for Future Changes A description of Entergys procedures for study of new facilities and their impacts on the interconnected transmission system and provisions for future changes are contained in the document. Transformer Pad 40x45x4 Single Phase (25-167KVA) . Daytona, Ormond, Seminole County, Orange County, Flagler, Tallahassee, Jacksonville, Tampa, Miami, Clearwater, Melbourne, Cocoa, Florida Keys. Looking for a quote for your project? From small stabilizing pads to large transformer foundations, Oldcaslte Infrastructure equipment pads are durable and convenient foundations for your equipment needs. outside the "clear line of sight triangle". 0000017234 00000 n This list is not all inclusive of the standards Advanced Energy may reference in an MV audit, but serves as a guide to help navigate the standards. Dimensions LxWxD inches. We use cookies to offer you a better browsing experience, analyze site traffic, personalize content, and serve targeted advertisements. Your file is uploaded and ready to be published. Ft. Lauderdale, West Palm, Palm Beach, Miami, Naples, and Ft. Myers. Precast concrete pads for Duke Energy small and large transformer pads. % DEC-Enterprise Wide 02-Poles, Guys and Anchors Many of the standards in the following subsections are applicable: This information is intended to provide . >> Performing this action will revert the following features to their default settings: Hooray! Listed by: mwrublewski. Languages English Age Rating 4+ Copyright 2022 Duke Energy Corporation Price Free App Support Overview From small stabilizing pads to large transformer foundations, Oldcaslte Infrastructure equipment pads are durable and convenient foundations for your equipment needs. Customer must be specific regarding 4-wire (grounded-wye) and 3-wire ("floatingwye") deliveries. <>>>/CropBox[0 0 612 792]/Rotate 0/VP[<>]/Subtype/RL/A[<>]/Type/Measure/R( )/D[<>]>>/Type/Viewport>>]/MediaBox[0 0 612 792]/Parent 49 0 R/Type/Page/Contents[62 0 R 61 0 R 60 0 R 59 0 R 58 0 R 57 0 R 68 0 R 67 0 R]>>
8285-Pit-Box-Pad-1.pdf. 0000008346 00000 n x[rGCL!r_e-mvv4%(X$k~ 'CrfUn>^(-t5{3|Zm])F9_rFMp. endobj A Self-Application Statement: The material contained in the documents which are referenced, or linked, within thisdocument is consistent in content and application to those requirements used by Entergy Transmission for connecting Entergy and Entergy Affiliated new or modified generation, new or modified transmission, and new or modified end-user facilities. Duke Energy 3-Phase Padmount Transformer Concrete Foundation Specifications July 2009 2. 0000013715 00000 n 0000016118 00000 n xc```a``=wA Magazine: 3-Phase Padmount Transformer Concrete Foundation - Duke Energy. . Florida, Georgia, North Carolina, South Carolina, Virginia, Alabama, Tennessee, Louisiana & Texas. pad-mounted transformer may require alternate means of fire protection including fire barriers, fire rated walls, oil 9. clearances listed are duke energy minimum requirements. 0000001729 00000 n Product Features 400 through 800 amp applications designed for bar type transformers 801 through 1200 amp applications designed for . Concrete Mix Specifications 1. This scope of the facilities covered are: Generation facilities Transmission facilities End-user facilities (only those connecting at or above 69 kV). 0000016338 00000 n little space in the secondary compartment of the transformer to accommodate excess cable. Note: 4-wire deliveries and 3-wire deliveries SHALL NOT be provided from the same transformer. However, in all cases, it is critical to maintain an open dialog between Duke Energy and the customer regarding conductor quantities, conduit sizes and locations, connections, and electrical load requirements. Hours. In cases where there are 3 secondary conductors per phase or fewer AND the conductors are less than or equal to 400 MCM, a "flat pad" may be considered. Read CaverManager, Transmission Project DevelopmentProject Management & Constructionccaver@entergy.com504-576-5506. 0000016643 00000 n Order Form. Click on photo to view larger. %PDF-1.3
%
While browsing our products, select Add to Quote Generator to quickly get an estimate for everything you need. 0000002098 00000 n Link:https://www.nerc.com/pa/Stand/Reliability%20Standards/FAC-001-3.pdf, #2. (Refer to the Padmount Clearance Standard for minimum distances from sides and back of concrete. /Root 53 0 R There shall be a minimum clearance of 10' from the front of the concrete pad to any walls, machinery, or other obstacles. . 0000015649 00000 n Key Reference #2 therefore can be compared side-by-side to Entergys main text and spreadsheet documents. Entergy will maintain this website as needed. In cases where there are 3 secondary conductors per phase or fewer AND the conductors are less than or equal to 400 MCM, a flat pad may be considered. The Entergy name and logo are registered service marks of Entergy Corporation and may not be used without the express, written consent of Entergy Corporation. The dimensions shall be in accordance with the specifications based on the transformer KVA size. uq)JJ?:bJ=s=e`VcRiAR9-'1lc[m" jk:cU
vZF}Drl"M6?wjp6jv=G G(\BA3_#};mJVc?=me_fj~l| \Dy In most cases, regardless of the KVA rating, the air compartment of all currently purchased transformers should cover the entire window opening of either pad. See how we're building a smarter, cleaner, more reliable energy future. 0000011547 00000 n xref List Price About Our Cabinets EMI, Inc. manufactures current transformer cabinets that meet the specific requirements of many utilities. 0000016686 00000 n While browsing our products, select Add to Quote Generator to quickly get an estimate for everything you need. Send us your complete form, then well give you a call to confirm the order & delivery details. The Duke Energy project coordinator will make the final decision whether it is permissible to use a flat pad. A separate secondary bus enclosure is required whenever the customer is installing more than ten (10) 600 MCM or smaller conductors per phase, or more than eight (8) conductors per phase that are larger than 600 MCM. . Duke Energy is a sustainable electric and gas company whose regulated operations serve 7.2 million U.S. customers in the Southeast and Midwest. 5) Barrier required for pit pad only. 12-26 Pad-mounted secondary cabinet (2 of 3) Spec. News/Blog 7. An alternative method is for the customer's conduit to be installed in the side of the pit. Read about how we use cookies and how you can control them by visiting our Cookie Statement. enclosed barriers if locked should be accessible at all times with key furnished to pepco. 3. Read about how we use cookies and how you can control them by visiting our Cookie Statement. 0000017686 00000 n /Info 50 0 R Do Not Sell Or Share My Personal Information, Offers a simple rugged design for a strong foundation. Distances are from the pad or transformer whichever is closer to the building or opening. Concrete mix used for Transformer Pads shall meet the following requirements: Minimum 28 day compressive strength of 3,000 psi Maximum water / cement ratio of 0.50 Maximum slump of 4 inches 55 and 55/65C average winding rise. 82"x85" Duke . If the customer's switchgear is at a level below the padmount transformer location, special arrangements must be made to prevent water from entering the customer's switchgear through the customer's conduits. 0000017159 00000 n Register for the portal today. 1 0 obj<>
endobj
2 0 obj<>
endobj
3 0 obj<>
endobj
4 0 obj<>
endobj
5 0 obj[]
endobj
6 0 obj<>
endobj
7 0 obj<>stream
XX>W 327703 Transformer Pad 40x45x4 Single Phase (25-167KVA), 327704 Transformer Pad 56x50x4 Single Phase, 327707Transformer Pad 75x60x7 3 Phase (75-500KVA), 327712 Transformer Pad 87x82x7 3 Phase (750-2500KVA), 2001315 Transformer Pad 40x45x4 1 Phase (25-50KVA), 2001316 Transformer Pad 52x44x4 1 Phase (75-250KVA), 2001317 Transformer Pad 66 x 74 x 4 3 Phase URD Transformer, 2001318 Transformer Pad 60 x 50 x 30 3 Phase 200 AMP DFSG, 2001319 Transformer Pad 75 x 86 x 36 3 Phase 600 AMP SG, 2001323 Transformer Pad 96 x 96 x 6 3 Phase URD Transformer, 2001324 Transformer Pad 96 x 76 x 6 3 Phase URD Transformer, 2001325 Transformer Pad 60 x 39 x 4 200A/600A SG Pad, 2117010 Transformer Pad 100 x 96 x 6 3 Phase URD transformer, Home Wall mount current transformer cabinets are available in several sizes and configurations ranging from 400 amps to 1200 amps. 0000016934 00000 n Additionally, the SERC Supplement, Key Reference #2 is applicable to both the FERC functional entity Transmission Owner and Applicable Generator Owner. Transmission consists of lines and facilities operated at or above the transmission voltage level of 69 kV (69,000 Volts). Add to . nsM7}a0W]hn6r{+zK_\RHR1Yc5jbj]J Employment Opportunities The thickness of all walls on the "pit pad" shall be a minimum of 5 - 1/2 thick. stream Customer Responsibilities The customer may choose to construct the transformer pad on site or purchase a prefabricated unit from a manufacturer. & 1500, 2000, 2500 15 service r 0000017353 00000 n Generation facilities, transmission facilities, and electric end-user facilities connected to Entergy within the SERC Region shall be required to remain in compliance with all applicable NERC Reliability Standards and SERC Supplements. You have already flagged this document.Thank you, for helping us keep this platform clean.The editors will have a look at it as soon as possible. startxref Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software. 1. %%EOF endstream Hours. Get started Our Company We power the lives of our customers and the vitality of our communities. 9T83C2572 - Photo of nameplate included in listing. 4905 Stough Road Concord, NC Phone (704) 788-4050. Your file is uploaded and ready to be published. 14 - 24 #4 Reinforcing Bars 6 min (Note 3) (Primary) See Note 5 (Secondary) 18 36 26 2 12 See Note 2 Duke Energy 3-Phase Padmount Transformer Concrete Foundation Specifications July 2009 6 70 18 6 See Note 2 94 10 Feet (Drawing Not To Scale) LARGE FLAT PAD & PIT PAD DIMENSIONS 94 94 WIDE LONG 1) Pad to be a Minimum of 5 - 1/2 Thick 2) Shaded area around pad indicates minimum clearance from obstructions. 0000016425 00000 n We use cookies to offer you a better browsing experience, analyze site traffic, personalize content, and serve targeted advertisements. 56 0 obj positioning of transformer should be at least 1 ft. higher than pad mount transformer. Pad-Mounted Transformers Optional Features & Accessories Broad selection of design efficiencies to meet specific customer applications and the new DOE efficiency requirements. 0000016600 00000 n Duke Energy Transformer Pads. %PDF-1.4 Contact You have already flagged this document.Thank you, for helping us keep this platform clean.The editors will have a look at it as soon as possible. Location Available. While browsing our products, select Add to Quote Generator to quickly get an estimate for everything you need. 0000006958 00000 n Often being constructed in less than a day, these pads are readily available for immediate installation without waiting for curing like pour-in-place alternatives. 4905 Stough Road Concord, NC Phone (704) 788-4050. Transformer Pad 40x45x4 Single Phase (25-167KVA), Transformer Pad 40x45x4 1 Phase (25-50KVA), Transformer Pad 52x44x4 1 Phase (75-250KVA), Transformer Pad 60 x 39 x 4 200A/600A SG Pad, Transformer Pad 75x60x7 3 Phase (75-500KVA), Transformer Pad 87x82x7 3 Phase (750-2500KVA), Transformer Pad 66 x 74 x 4 3 Phase URD Transformer, Transformer Pad 96 x 76 x 6 3 Phase URD Transformer, Transformer Pad 96 x 96 x 6 3 Phase URD Transformer, Transformer Pad 100 x 96 x 6 3 Phase URD transformer. Duke Energy 3-Phase Padmount Transformer Concrete Foundation Specifications July 2009 1, Customer Responsibilities (continued) 4. Consider a LARGE pad in applications where the number of customer conduits/conductors exceeds the window opening restrictions of the SMALL pad, and when load growth and/or a transformer change-out to a larger size is anticipated. 11-2 Secondary connectors single-phase URD pad-mount transformer. . 0000012789 00000 n 0000017567 00000 n Refer to the Padmount Building Clearance Standard for the minimum allowable distance between transformer pads and buildings, building openings and equipment. 0000017488 00000 n Full Construction Standards Division 00 - Procurement and Contracting Requirements Division 01 - General Requirements Division 02 - Existing Conditions Division 03 - Concrete Division 04 - Masonry Division 05 - Metals Division 06 - Wood, Plastics, and Composites Division 07 - Thermal and Moisture Protection Division 08 - Openings <> Customer shall inform Duke Energy of the number, size, and type of secondary conductors that will be installed. Access to documents that are deemed confidential is available to parties with a need to know who agree to abide by and sign appropriate confidentiality agreements.
Duke Ortho Residency,
Peter Thomas Net Worth Forensic Files,
Monument Mountain Regional High School,
Why Was Man Down Cancelled,
Articles D